Good Quality Analyzer Chemistry Chemistry Analyzer M4 Jinan MSLBA67

Analysis System
Optical System
Sample adding and rinsing system
Mixing and washing system
Reagent/Sample Tray
Operation System
Performance
Type: Discrete Automatic, Random Access
Principle: Absorption Spectrometry, Turbidimetry
Throughput: Constant 200tests/hour (without ISE)
Test Method: End-point, Fixed-time, kinetic
Test Sequence: Run tests in strict accordance with sample sequence,
Insert emergency at any time
Optical System
Light Source: Halogen-tungsten lamp, 12V/20W
More than 2000hrs service time
Spectrometric Method: After spectrometric method
Wavelength: 8 wavelengths, selectable among 340-800nm
Detector: Photodiode array
Absorption Range: 0-4.0Abs
Optical System: Integrated full closed optical system
Reaction system
Reaction Tray: 81 positions
Reaction Volume: Mini 150μl
Sample system
Sample Tray: 30 positions
Sample Volume: 2-100μl , 0.1μl by step
Online Sample: 60 samples/ batch, unlimited batch input
Reagent System
Reaction Tray: 60 positions, open system
Reagent Volume: 20-500μl, 1μl by step
Reagent Bottle: Bottles with 15ml and 30ml are available, dead volume<0.5ml
Temperature Control System
Heating Mode: Solid constant temperature closed direct heating
Heating Time: less than 3minutes
Reaction Temperature: 37±0.2°C
Temperature Fluctuation: ± 0.1°C
Refrigeration system: 24 hours cooling for reagent tray, temperature: 4-12°C
Calibration and QC
Calibration Mode: Linear, Logit-4p, Logit-5p, Spline, Factor, Polynomial
Automatically check calibration curve
and fitting the best calibration curve
QC Type: Multi-type
QC Rules: Multi-rule; default: Westguard
Status Monitoring: Real -time monitor the sample tray, reagent tray, reaction tray; Real-time display reaction tray humidity, reagent remain,
reaction curve, calibration curve and QC chart.
Inspection and Judgment: Reaction end point judgment, reaction linear range judgment,
substrate depletion judgment, reagent blank absorbance judgment
Operation and Print
Operation System: Windows XP or Windows 7 Home
Database: SQL Server
Data Storage: Automatic storage and backup,
permanently preserve all kinds of data
Print Content: Print content can be customized
Print Format: Provide a variety of print format
Working Conditions
Water Consumption: less than 5L/hour
Power Supply: AC 220 ±22V 50HZ ±1HZ
Power: Max 200VA
Ambient Temperature: 15°C-30°C
Dimension(L*W*H): 79*59*108cm
Net Weight: 90KGS

Features
- Random access, discrete automatic biochemistry analyzer, Insert emergency at any time
- High performance and reasonable price, It is the good economic choice from semi-auto upgraded to fully-auto analyzer
- Probe performance: Liquid level detection, all-round anti-collision protection and inventory checking, have automatic stop and alarm prompt for an obstacle
- Probe cleaning: Automatic washing for both interior and exterior
- Separate mixer, Auto washing, 24hours refrigeration system
Analysis System
- Constant 200tests/hour, up to 320tests/hour
- Test method: End-point, Fixed-time (two point method), kinetic
- Reaction tray: 81 UV cuvettes, reusable
- Mini reaction volume: 150μl, save reagent cost
- Insert emergency at any time
- Support linear and non-linear calibration
- Heating method: solid constant temperature closed direct heating
- Temperature equilibrium time: less than 3minutes,
- Reaction Temperature: 37±0.2°C
- Temperature Fluctuation: ± 0.1°C
Optical System
- Integrated full closed optical system, no mechanical parts, not moldy, no maintenance cost
- 8 wavelengths, selectable among 340-800nm, after spectrometric method
- Absorption range: 0.00-4.00Abs
- Halogen-tungsten lamp has more than 2000hrs service time
- Center wavelength deviation: ±2nm, half wave width less than 12nm
- Stray light less than 0.3%
- Resolution: 0.0001Abs
Sample adding and rinsing system
- Sample volume: 2- 100μl, 0.1μl by step
- Reagent volume: 20-500μl, 1μl by step
- Water consumption: less than 5L/hour
Mixing and washing system
- Mixing system: separate mixer, to mix the sample and reagent completely,
- Washing system: single needle to wash cuvettes one by one automatically
Reagent/Sample Tray
- 60 reagent + 30 sample positions
- Advanced reagent tray refrigeration system, temperature: 4-12°C
- Automatically detect reagent remain, real time display reagent remain
- Reagent bottles with 15ml and 30mlare available, dead volume<0.5ml
- Support single/ dual reagents, reagents are open
- Real time display reagent tray status
- Automatically judge substrate depletion and automatically dilute and retest
Operation System
- Windows XP or Windows 7 Home, easy to operate
- Set the operating authority, no time limit and storage limit,
- Permanently preserve all kinds of data
- Automatic storage, automatic backup,
- English print report, the user can modify the print format
- English online help and operation guide
- The test parameter setting is completely open
- The unique user password management, reasonable distribute the operating authority
- Real-time display the status of sample testing, reagent remain, reaction tray and reaction curve recording
- Real-time understand the testing progress
- Automatically check calibration curve and fitting the best calibration curve
- Calibration Mode: Linear, Logit-4p, Logit-5p, Spline, Factor, Polynomial
- The computing items can be set randomly, automatically judge substrate depletion, automatically retest
- Real-time display the reaction tray temperature
- RS232 standard interface, support the intranet and remote printing
Performance
Type: Discrete Automatic, Random Access
Principle: Absorption Spectrometry, Turbidimetry
Throughput: Constant 200tests/hour (without ISE)
Test Method: End-point, Fixed-time, kinetic
Test Sequence: Run tests in strict accordance with sample sequence,
Insert emergency at any time
Optical System
Light Source: Halogen-tungsten lamp, 12V/20W
More than 2000hrs service time
Spectrometric Method: After spectrometric method
Wavelength: 8 wavelengths, selectable among 340-800nm
Detector: Photodiode array
Absorption Range: 0-4.0Abs
Optical System: Integrated full closed optical system
Reaction system
Reaction Tray: 81 positions
Reaction Volume: Mini 150μl
Sample system
Sample Tray: 30 positions
Sample Volume: 2-100μl , 0.1μl by step
Online Sample: 60 samples/ batch, unlimited batch input
Reagent System
Reaction Tray: 60 positions, open system
Reagent Volume: 20-500μl, 1μl by step
Reagent Bottle: Bottles with 15ml and 30ml are available, dead volume<0.5ml
Temperature Control System
Heating Mode: Solid constant temperature closed direct heating
Heating Time: less than 3minutes
Reaction Temperature: 37±0.2°C
Temperature Fluctuation: ± 0.1°C
Refrigeration system: 24 hours cooling for reagent tray, temperature: 4-12°C
Calibration and QC
Calibration Mode: Linear, Logit-4p, Logit-5p, Spline, Factor, Polynomial
Automatically check calibration curve
and fitting the best calibration curve
QC Type: Multi-type
QC Rules: Multi-rule; default: Westguard
Status Monitoring: Real -time monitor the sample tray, reagent tray, reaction tray; Real-time display reaction tray humidity, reagent remain,
reaction curve, calibration curve and QC chart.
Inspection and Judgment: Reaction end point judgment, reaction linear range judgment,
substrate depletion judgment, reagent blank absorbance judgment
Operation and Print
Operation System: Windows XP or Windows 7 Home
Database: SQL Server
Data Storage: Automatic storage and backup,
permanently preserve all kinds of data
Print Content: Print content can be customized
Print Format: Provide a variety of print format
Working Conditions
Water Consumption: less than 5L/hour
Power Supply: AC 220 ±22V 50HZ ±1HZ
Power: Max 200VA
Ambient Temperature: 15°C-30°C
Dimension(L*W*H): 79*59*108cm
Net Weight: 90KGS